THERMAL LAB · WW-01 · WORKING WITH THE LAB

Writing a thermal brief

A brief tells us what your product has to do and where. One page is enough. The clearer the brief, the smaller and more useful the first program will be.

In this section
  1. WW-01 Writing a thermal brief
  2. WW-02 Confidentiality and ownership
  3. WW-03 Licensing the architecture
  4. WW-04 Lab questions and answers

The seven questions

1. What has to stay at what temperature? A person's torso comfortable. A battery above 5 °C (41 °F). A payload between 2 and 8 °C (36 and 46 °F). Give a target and an acceptable band.

2. In what surroundings? The coldest and hottest air temperatures, wind, sun, moisture, and what the item rests on or is worn under.

3. For how long? Duration of a single use, and how many uses between charging or resupply.

4. With what energy? Battery capacity available, or none. Access to wall or vehicle power. Whether consumable heat sources are acceptable.

5. Inside what limits? Maximum thickness and weight. Surface temperature limits. Regulations on materials, attire or transport.

6. What exists now? A current product or prototype, what it does well and what users complain about.

7. What decision will the result support? Choosing between suppliers. Proving a design before tooling. Supporting a customer claim. Finding out why something underperforms.

What not to worry about

You do not need to propose a test method. That is our part. You do not need thermal vocabulary. A plain description of the situation is better than a specification written in guesses.

What to hold back

Send nothing confidential before a nondisclosure agreement is signed. The first message needs only the field, the general problem and how to reach you. See confidentiality and ownership.

A short example

A maker of a portable instrument writes: the unit is stored in an unheated vehicle overnight at down to -20 °C (-4 °F), has to be ready within ten minutes of pickup, runs on its own 50 Wh battery and cannot grow by more than 5 mm in any dimension. Current units fail to start below about -5 °C (23 °F). The decision is whether insulation and a small heater can solve it or whether the battery has to change.

That is a complete brief.

What happens next

We reply with questions if needed, then a scope and proposal that states what we will measure, what you will receive and what it costs. Small first programs are usual.

Related: the five jobs of a thermal system and reading a thermal report.

Put the lab to work.

Send a brief. A mutual nondisclosure agreement comes first.

Start a program