What is the difference between R-value, clo and tog?
R-value, clo and tog are three units for the same thing, thermal resistance, which is how strongly a layer resists heat passing through it. R-value is used for buildings and sleeping pads, clo for clothing and tog for duvets and some textiles. They convert directly into one another.
The common basis
Thermal resistance in SI units is given in square meter kelvin per watt, m²·K/W. A higher number means better insulation. Each of the three everyday units is a fixed multiple of it.
| Unit | Equals in m²·K/W | Used for |
|---|---|---|
| 1 tog | 0.1 | Duvets, sleep sacks, carpets |
| 1 clo | 0.155 | Clothing |
| 1 U.S. R-value | 0.176 | Buildings, sleeping pads |
| 1 SI R-value (RSI) | 1.0 | Buildings outside the U.S. |
Conversion table
| From | To clo | To tog | To U.S. R-value |
|---|---|---|---|
| 1 clo | 1 | 1.55 | 0.88 |
| 1 tog | 0.645 | 1 | 0.57 |
| 1 U.S. R-value | 1.14 | 1.76 | 1 |
What is clo?
Clo was defined in 1941 as the insulation of a typical business suit, enough to keep a resting person comfortable in a room at about 21 °C (70 °F). A naked body is 0 clo. Summer clothing is around 0.5 clo. Heavy arctic clothing reaches 3 to 4 clo. See clo value explained and our clo values clothing table.
What is tog?
Tog was introduced in Britain in the 1940s as a simpler unit for textiles. It is most familiar on duvets and children’s sleep sacks.
| Item | Typical tog |
|---|---|
| Summer duvet | 3 to 4.5 |
| All-season duvet | 7 to 10.5 |
| Winter duvet | 12 to 15 |
| Baby sleep sack, warm room | 0.5 to 1 |
| Baby sleep sack, cool room | 2.5 |
What is R-value?
R-value is thermal resistance as used in construction. In the United States it is given in ft²·°F·h/BTU. Elsewhere the SI version, sometimes written RSI, is used, and it is about 5.68 times larger for the same insulation. Wall insulation runs from about R-13 to R-21 in U.S. units. Sleeping pads are rated from about R-1 for summer to R-5 and above for winter.
Why three units?
Each grew up in a different industry with its own test method. Clothing is tested on heated manikins and hot plates. Duvets are tested on a flat hot plate. Building insulation is tested with heat flow meters. The physics is the same.
What these numbers leave out
All three describe resistance to dry heat flow under still test conditions. They do not capture:
- Wind, which strips the still air layer from the outside of clothing.
- Movement, which pumps warm air out.
- Moisture, which lowers insulation and adds evaporative cooling.
- Compression, such as a sleeping bag under body weight.
- Radiant effects, such as a heat-reflective layer facing an air gap.
A rating is a starting point for comparison, not a prediction of comfort.
Key takeaways
- R-value, clo and tog all measure thermal resistance.
- 1 clo equals 1.55 tog and 0.88 U.S. R-value.
- Clo is for clothing, tog for bedding, R-value for buildings and sleeping pads.
- U.S. and SI R-values differ by a factor of about 5.68.
- Ratings assume still, dry test conditions.
FAQ
How many tog is 1 clo?
1.55 tog.
Is a higher tog warmer?
Yes. Higher tog, clo or R-value all mean more insulation.
Can I add ratings together?
Approximately, for layers. Two blankets of 4 tog give roughly 8 tog. With clothing, layers compress each other and trap extra air, so the total is an estimate.
What R-value sleeping pad do I need for winter?
Pads rated around R-4 to R-5 or higher are generally recommended for camping on frozen ground or snow.
What tog should a baby sleep sack be?
It depends on room temperature. Makers typically suggest about 2.5 tog for rooms of 16 to 20 °C (61 to 68 °F) and 1 tog or less for warmer rooms. Follow the maker’s chart and current infant sleep guidance from your health authority.
Related reading
Sources
- Gagge, Burton and Bazett, A practical system of units for the description of the heat exchange of man with his environment, Science (1941)
- ISO 9920, Ergonomics of the thermal environment: Estimation of thermal insulation and water vapour resistance of a clothing ensemble
- BS 4745, Determination of the thermal resistance of textiles (tog)
- ASTM F3340, Standard Test Method for Thermal Resistance of Camping Mattresses Using a Guarded Hot Plate Apparatus
- ASHRAE Handbook: Fundamentals