What is thermal resistance, and how do you calculate it?

Science of WarmthUpdated 10 min read

Thermal resistance is a measure of how strongly a layer or an assembly opposes the flow of heat. It equals the temperature difference across the layer divided by the heat flowing through it, in kelvin per watt (K/W). Engineers stack resistances like electrical resistors to predict heat loss through walls, enclosures and clothing.

What is thermal resistance in simple terms?

Heat moves from warm to cold whenever there is a temperature difference. Thermal resistance describes how hard that movement is. A layer with high thermal resistance lets only a trickle of heat through for a given temperature difference. A layer with low thermal resistance lets heat pour through.

The idea maps directly onto electricity. In a circuit, voltage drives current through a resistor. In heat transfer, a temperature difference drives heat flow through a thermal resistance. The thermal version of Ohm’s law is:

Q = ΔT / R

Here Q is the heat flow in watts, ΔT is the temperature difference in kelvin (a difference of 1 K is the same as 1 °C, or 1.8 °F), and R is the thermal resistance in K/W. The MIT-hosted A Heat Transfer Textbook builds its whole treatment of steady conduction on this analogy, because it lets engineers draw a “thermal circuit” and solve it with the same rules used for electrical circuits.

Thermal resistance is a property of a specific piece of material with a specific thickness and area. That is the key difference from thermal conductivity, which is a property of the material itself, independent of its size.

What is the formula for thermal resistance?

For heat conducting straight through a flat layer, thermal resistance depends on three things: thickness, conductivity and area.

R = L / (k × A)

  • L is the thickness in meters. Doubling the thickness doubles the resistance.

  • k is the thermal conductivity in W/(m·K). A material with half the conductivity gives twice the resistance at the same thickness.

  • A is the area heat flows through, in m². A larger area offers more parallel paths, so resistance falls.

Because area changes from one product to the next, engineers often drop it and quote the area-specific thermal resistance, R = L / k, in m²·K/W. This is the number building codes call the R-value (in SI units) and the number textile labs report for fabrics. To get back to K/W for a real part, divide the area-specific value by the part’s area.

Heat leaving a surface into air or water also meets a resistance, set by the heat transfer coefficient h. That surface or boundary-layer resistance is R = 1 / (h × A), or 1 / h per square meter. In still air the film on a surface often supplies a meaningful share of the total resistance. In wind it shrinks sharply, which is part of why wind makes the same clothing feel colder.

What units is thermal resistance measured in?

Several units are in common use, and mixing them up is a frequent source of error in specifications. The table converts the main ones to SI area-specific resistance.

UnitWhat it describesEquals, in m²·K/W
K/WAbsolute resistance of a whole part or jointNot area based, divide m²·K/W by area to convert
m²·K/WArea-specific resistance (SI R-value, fabric Rct)1
US R-value, ft²·°F·h/BtuBuilding insulation in the United States0.1761
cloClothing insulation0.155
togBedding and textile insulation0.1

A useful cross-check is that 1 clo equals 1.55 tog and about 0.88 US R-value. Our guide to R-value, clo and tog walks through when each unit is used, and the clo value explainer covers how clothing insulation is rated. Area-specific resistance also links directly to heat flux: flux in W/m² equals ΔT divided by area-specific R.

How do thermal resistances add in series and parallel?

When heat must pass through one layer after another, the resistances are in series and they simply add. When heat can take two or more side-by-side paths, the resistances are in parallel and their reciprocals add, exactly as with electrical resistors.

Worked example, series. Consider the wall of a small field equipment enclosure kept at 5 °C (41 °F) inside while the outside air is -20 °C (-4 °F). That is a 25 K difference. Per square meter, the wall has four resistances in a row:

LayerCalculationArea-specific R, m²·K/W
Inside air film, h of 5 W/(m²·K)1 / 50.200
Polycarbonate shell, 2 mm, k of 0.20 W/(m·K)0.002 / 0.200.010
Closed-cell foam, 20 mm, k of 0.035 W/(m·K)0.020 / 0.0350.571
Outside air film in light wind, h of 10 W/(m²·K)1 / 100.100
TotalSum of the layers0.881

The heat flux is 25 / 0.881, about 28 W/m². If the enclosure has 0.25 m² of wall, its absolute resistance is 0.881 / 0.25, about 3.5 K/W, and it loses about 7.1 W once temperatures settle. That is the steady power a heater inside must supply to hold 5 °C (41 °F). The foam carries most of the resistance, and the two air films together add about a third more.

Worked example, parallel. Now add a metal mounting bracket that passes through the foam. Suppose the metal crossing the foam totals 1 cm² of aluminum, with k of about 205 W/(m·K). Its resistance across the 20 mm core is 0.020 / (205 × 0.0001), about 0.98 K/W. The foam over the rest of the area has about 2.29 K/W. In parallel, 1 / (1 / 0.98 + 1 / 2.29) gives about 0.68 K/W, a drop of roughly 70 percent in the core’s resistance. With the shell and air films added in series, the whole wall falls from about 3.5 K/W to about 1.9 K/W, and heat loss rises from about 7 W to about 13 W. This is an idealized estimate, since real heat also spreads sideways, but it shows why a single thermal bridge can dominate a well-insulated design.

Clothing behaves the same way. A thick jacket is a series stack of fabric, trapped air and surface film. A gap at the collar or a compressed area under a strap is a low-resistance parallel path. The conductivity of each material sets the starting point, but layout decides the result.

What is thermal contact resistance?

When two solid surfaces touch, they meet only at the high points of their roughness. Most of the apparent contact area is actually a thin gap filled with air. Heat crossing the joint must squeeze through the small true contact spots or cross the gap, so the joint adds its own resistance, called thermal contact resistance.

Heat transfer textbooks report contact conductance values that vary by more than a factor of ten with clamping pressure, surface finish, hardness and whatever fills the gap. Practical consequences follow:

  • Pressure lowers it. Clamping harder flattens the high points and enlarges the true contact area.

  • Fillers lower it. Thermal pastes, pads and gap fillers replace air, which conducts poorly, with a material that conducts better.

  • It matters most where layers are thin. In a heater bonded to a battery pack or a sensor pressed to skin, the contact layer can rival the resistance of the parts themselves.

The same principle explains why a warmer works better pressed close to the body than floating in a loose pocket. An air gap is a resistance in series between the heat source and the skin.

How is thermal resistance measured?

Standard methods exist for each kind of specimen. Each holds a known temperature difference, measures heat flow, and divides one by the other.

MethodWhat it testsHow it works
ASTM C177, guarded hot plateFlat, homogeneous insulation specimensA primary, absolute method. A heated plate with a guard ring sends a known heat flux through the specimen to a cold plate.
ASTM C518, heat flow meterFlat insulation slabs, quicklyA comparative method calibrated with reference materials such as NIST SRM 1450d fibrous glass board.
ISO 11092, sweating guarded hotplateFabrics, films and layered textilesReports thermal resistance Rct in m²·K/W and water-vapor resistance Ret in m²·Pa/W.
ASTM F1291, heated manikinWhole clothing ensemblesMeasures resistance to dry heat loss from a heated manikin to a calm, cool room, reported in clo or m²·K/W.

Two details trip up buyers comparing data sheets. First, some results include the surface air layer and some subtract it, so a fabric’s intrinsic resistance is lower than the total measured on the plate. Second, every result applies only to its test conditions. ASTM F1291 states plainly that values apply to the ensembles and conditions tested, particularly air movement. Our explainer on how clothing warmth is tested covers the textile and manikin methods in more depth.

The HEATJAC Thermal Lab helps companies characterize products for cold and heat, measuring warm-up behavior, temperature distribution, stability and energy use with thermal imaging and multi-point temperature logging. Learn about the Thermal Lab.

Key takeaways

  • Thermal resistance is temperature difference divided by heat flow, in K/W for a whole part or m²·K/W per unit area.

  • For a flat layer, R = L / (k × A). Thicker layers and lower conductivity both raise resistance.

  • Resistances in series add. Parallel paths combine like parallel resistors, so a small thermal bridge can cut total resistance sharply.

  • Surface air films and contact joints are real resistances and belong in every calculation.

  • 1 clo equals 0.155 m²·K/W, 1 tog equals 0.1 m²·K/W, and 1 US R-value equals 0.1761 m²·K/W.

  • ASTM C177, ASTM C518, ISO 11092 and ASTM F1291 cover insulation slabs, textiles and whole garments.

Frequently asked questions

What is the difference between thermal resistance and thermal conductivity?

Thermal conductivity, k, is a property of a material, in W/(m·K). Thermal resistance is a property of a particular layer or part and depends on its thickness and area as well as its conductivity. A thin sheet of a good insulator can have lower resistance than a thick block of a poorer one.

What are the units of thermal resistance?

Absolute thermal resistance is in kelvin per watt (K/W), which is the same as °C per watt. Area-specific thermal resistance is in m²·K/W. Clothing uses clo (0.155 m²·K/W) and bedding uses tog (0.1 m²·K/W).

What is Rct in fabric testing?

Rct is the thermal resistance of a textile measured on a sweating guarded hotplate under ISO 11092, in m²·K/W. The same test reports Ret, the water-vapor resistance, which describes how easily sweat vapor escapes.

How do you calculate the total thermal resistance of several layers?

Add the resistances of layers that heat crosses one after another, including the air films on each side. For side-by-side paths, add the reciprocals and invert the result. Then divide the temperature difference by the total to find heat flow.

Does higher thermal resistance mean warmer?

For clothing, yes, at a given activity and climate. Higher resistance slows heat loss from the body, so the same metabolic heat keeps you warmer. Wind, moisture and compression all lower effective resistance, so real-world warmth depends on fit and conditions as well as the rated value.

Sources

  1. A Heat Transfer Textbook, 6th edition, Massachusetts Institute of Technology

  2. ASTM C177: Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus, ASTM International

  3. ASTM C518: Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, ASTM International

  4. ISO 11092:2026: Textiles, Physiological effects, Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test), International Organization for Standardization

  5. ASTM F1291: Standard Test Method for Measuring the Thermal Insulation of Clothing Using a Heated Manikin, ASTM International

  6. Standard Reference Material 1450d, Fibrous Glass Board, for Thermal Insulation Measurements, National Institute of Standards and Technology

About HEATJAC. HEATJAC is a thermal architecture company founded by an anesthesiologist. We design garment systems that help the body keep its own heat and spread added warmth across the torso, and we publish this knowledge hub because the science of staying warm should be public. HEATJAC products are not medical devices and are not intended to diagnose, treat, cure or prevent any disease.