What is a heat transfer coefficient, and how does it shape body and product heat loss?
A heat transfer coefficient tells you how many watts flow across each square meter of surface for every degree of temperature difference, written as W/(m²·K). A resting person in still indoor air has a combined value near 8 W/(m²·K); wind can push the convective part several times higher.
What is a heat transfer coefficient?
Heat moves from a warm surface to cooler surroundings at a rate that depends on three things: how large the surface is, how big the temperature difference is, and how easily heat crosses the boundary. The heat transfer coefficient, written h, captures that third factor in a single number. The basic relationship is:
q = h × A × ΔT
Here q is the heat flow in watts, A is the surface area in square meters and ΔT is the temperature difference between the surface and the surroundings in kelvin (a step of 1 K is the same size as a step of 1 °C). The units of h are therefore watts per square meter per kelvin, W/(m²·K). A surface with h = 10 W/(m²·K) and an area of 1 m² loses 10 W for every degree it sits above its surroundings.
The term “heat loss coefficient” is often used for the same idea when the focus is on how fast a body, a building or a box loses heat. In engineering practice the area should always be stated alongside the coefficient, a point the ASHRAE Handbook makes explicitly for the overall coefficient U.
The coefficient is not a fixed property of a material. It describes a surface in a particular situation: the same jacket sleeve has one value in a still room and a much higher one on a windy ridge. That is why the same garment can feel warm indoors and thin outdoors, as we explain in how the body loses heat.
What is the difference between the convective and radiative coefficients?
A warm surface in air loses heat in two parallel ways, and each gets its own coefficient. The convective coefficient, hc, describes heat carried away by moving air. The radiative coefficient, hr, describes infrared energy exchanged with surrounding surfaces such as walls, sky and ground. Because they act side by side, they add: h = hc + hr. ASHRAE’s thermal comfort chapter uses exactly this combined coefficient for people.
Convection. In still air, warm air next to the skin rises on its own, a process called natural or free convection. A 1997 study by de Dear and colleagues at the University of California, Berkeley, measured a thermal manikin segment by segment and found whole-body natural convection coefficients of 3.3 W/(m²·K) seated and 3.4 W/(m²·K) standing. When air moves past the body, forced convection takes over and hc rises with air speed. For indoor air speeds of roughly 0.2 to 0.8 m/s, the same study gives hc = 10.3 v0.6, with v in meters per second. ASHRAE gives a related correlation for a standing person in moving air of hc = 14.8 v0.69 in SI units, valid from about 0.15 to 1.5 m/s.
Radiation. The radiative coefficient is a linearized version of the Stefan-Boltzmann law. It scales with the emissivity of the surface and roughly with the cube of absolute temperature, so it changes little across normal indoor conditions. de Dear and colleagues measured 4.5 W/(m²·K) for the whole body, seated or standing, and ASHRAE states that a value of about 4.7 W/(m²·K) suffices for most calculations. A low-emissivity surface lowers hr, which is the physics behind heat-reflective layers; see what emissivity means.
What are typical heat transfer coefficient values?
Values span several orders of magnitude, from a few watts per square meter per kelvin for still air to tens of thousands for boiling water. The table below collects figures relevant to people and to small products in air.
| Situation | Typical h, W/(m²·K) | Source note |
|---|---|---|
| Person seated, still air (natural convection) | 3.3 | de Dear et al., 1997 |
| Person standing, still air (natural convection) | 3.4 | de Dear et al., 1997 |
| Person indoors, air at 0.5 m/s (forced convection) | About 6.8, from 10.3 v0.6 | de Dear et al., 1997 |
| Person standing, air at 1.5 m/s (forced convection) | About 20, from 14.8 v0.69 | ASHRAE Fundamentals, Thermal Comfort |
| Person, radiative exchange indoors | 4.5 to 4.7 | de Dear et al., 1997; ASHRAE |
| Any surface, free convection in gases | 2 to 25 | ASHRAE Fundamentals, Heat Transfer |
| Any surface, forced convection in gases | 25 to 250 | ASHRAE Fundamentals, Heat Transfer |
| Forced convection in liquids | 50 to 20,000 | ASHRAE Fundamentals, Heat Transfer |
Two patterns stand out. First, radiation accounts for more than half of a resting person’s surface heat transfer in still indoor air, because 4.5 is larger than 3.4. Second, moving air quickly makes convection the dominant path. Steady outdoor wind pushes values toward the forced-convection range for gases, which is the effect that wind chill tries to express as a single feels-like temperature. Water is far more aggressive than air, which is why immersion cools the body so fast; conductive heat loss covers the related case of direct contact.
How do the overall coefficient U and thermal resistance work?
Real systems have more than one barrier in the path of heat. A torso loses heat through a base layer, an insulating layer, a shell and finally the air film on the outside. A battery box loses heat through its inner air space, its wall and its outer surface. Engineers handle these chains with thermal resistance, the inverse of a coefficient:
R = 1 / h for a surface, and R = L / k for a solid layer of thickness L and thermal conductivity k.
Resistances in series simply add, the same way electrical resistors do, and ASHRAE notes that the same circuit methods apply. The overall heat transfer coefficient is the inverse of the total:
U = 1 / (R1 + R2 + R3 + …)
Clothing science uses the same arithmetic with its own unit. One clo equals 0.155 m²·K/W, a definition shared by ISO 9920 and the ASHRAE Handbook. ISO 9920 also defines the insulation of the outer air layer as Ia = 1 / (hc + hr), so the surface coefficient drops straight into a clothing calculation. In still indoor air, with h near 7.9 W/(m²·K), that air layer alone is worth about 0.13 m²·K/W, or roughly 0.8 clo. Our guide to clo value explains how garment ratings are built from these layers, and the clothing microclimate describes the trapped air that does most of the insulating.
Because resistances add, the weakest link sets the pace. Adding insulation helps most where the existing path is the least resistive, and a thin outer layer that blocks wind can matter more than extra loft underneath it, because it protects the still air inside.
How much heat does a torso lose? A worked example
This is a simplified illustration, not a physiological model. Assume a torso surface of 0.5 m², a skin temperature of 33 °C (91 °F), air and surrounding surfaces at 20 °C (68 °F), and a temperature difference of 13 K. Sweating, breathing and clothing area effects are ignored.
- Bare skin, still air. h = 3.4 + 4.5 = 7.9 W/(m²·K). Heat flow is 7.9 × 0.5 × 13, or about 51 W.
- One clo of clothing, still air. Total resistance is 0.155 + 1/7.9 = 0.282 m²·K/W. Heat flow is 0.5 × 13 / 0.282, or about 23 W, less than half.
- Bare skin, 1.5 m/s breeze. hc rises to about 19.6, so h = 24.1 W/(m²·K). Heat flow is about 157 W, three times the still-air figure.
- One clo, same breeze. Total resistance is 0.155 + 1/24.1 = 0.197 m²·K/W. Heat flow is about 33 W.
The insulation layer absorbs most of the change, which is the job it is designed to do. In practice wind also compresses and penetrates clothing, so the real clothed figure in wind is higher than this ideal case. Laboratory methods for measuring that are covered in how clothing warmth is tested.
How does the coefficient apply to a small equipment enclosure?
The same arithmetic sizes the heater for a battery box or a sensor housing. Take a box 20 × 15 × 10 cm with a surface area of 0.13 m², held at 20 °C (68 °F) inside while the air outside is −20 °C (−4 °F), a difference of 40 K.
- Thin shell only. Assume an inside surface coefficient of 5 W/(m²·K) (R = 0.20) and an outside coefficient of 25 W/(m²·K) in light wind (R = 0.04). U = 1 / 0.24, or about 4.2 W/(m²·K). Heat loss is 4.2 × 0.13 × 40, or about 22 W.
- Add 2 cm of expanded polystyrene. NIST measures this material at about 0.033 W/(m·K) near room temperature, so the wall adds R = 0.02 / 0.033, about 0.61. U falls to about 1.2 W/(m²·K) and heat loss to about 6 W.
Two centimeters of foam cut the steady heating demand by more than two thirds. The heater, the battery capacity reserved for it and the control strategy can all be sized from that single U value, before any prototype exists. Edges, cable entries and fasteners act as thermal bridges, so measured losses typically run higher than the ideal wall calculation.
Engineering teams that need measured values rather than estimates can work with HEATJAC’s Thermal Lab, which measures warm-up behavior, temperature distribution, stability over time and energy use using thermal imaging and multi-point temperature logging.
Key takeaways
- A heat transfer coefficient, h, links heat flow to area and temperature difference: q = h × A × ΔT, in W/(m²·K).
- For a person in air, convection and radiation act in parallel and add; still indoor air gives about 3.4 + 4.5, or near 8 W/(m²·K).
- Air movement raises the convective part quickly; wind can triple bare-skin heat loss.
- Thermal resistance is the inverse of a coefficient, and resistances in series add. One clo is 0.155 m²·K/W.
- The same method sizes heaters and insulation for equipment enclosures, wearables and payloads.
Frequently asked questions
Is a heat transfer coefficient the same as thermal conductivity?
No. Thermal conductivity, k, is a property of a material and has units of W/(m·K). A heat transfer coefficient describes a surface or a whole path in a given situation and has units of W/(m²·K). A layer of thickness L contributes a coefficient of k / L.
What is the difference between a heat transfer coefficient and a heat loss coefficient?
They describe the same quantity. “Heat loss coefficient” is common in building and product contexts when the focus is on how quickly an object loses heat to its surroundings, often stated as an overall U value.
What is the radiative heat transfer coefficient of the human body?
Measurements on a thermal manikin give about 4.5 W/(m²·K) for the whole body, and ASHRAE uses about 4.7 W/(m²·K) for typical indoor calculations. The value rises with surface emissivity and with temperature.
How does wind change the heat transfer coefficient?
Wind thins the warm air layer next to a surface, so the convective coefficient grows with air speed. For a standing person, ASHRAE’s correlation rises from about 5 W/(m²·K) at 0.2 m/s to about 20 W/(m²·K) at 1.5 m/s.
How is thermal resistance related to clo?
Clo is a unit of thermal resistance used for clothing. One clo equals 0.155 m²·K/W, so a 1 clo outfit resists heat flow about as much as a still air layer with a coefficient of 6.5 W/(m²·K).
Related reading
Sources
- Convective and radiative heat transfer coefficients for individual human body segments, de Dear, Arens, Zhang and Oguro, International Journal of Biometeorology 40:141-156 (1997)
- ASHRAE Handbook, Fundamentals, Chapter 4: Heat Transfer, ASHRAE (2021)
- ASHRAE Handbook, Fundamentals, Chapter 9: Thermal Comfort, ASHRAE (2017)
- ISO 9920: Ergonomics of the thermal environment, estimation of thermal insulation and water vapour resistance of a clothing ensemble, International Organization for Standardization (2007)
- Standard Reference Materials: SRM 1453a, Expanded Polystyrene Board for Thermal Conductivity (NIST SP 260-261), National Institute of Standards and Technology (2026)
About HEATJAC. HEATJAC is a thermal architecture company founded by an anesthesiologist. We design garment systems that help the body keep its own heat and spread added warmth across the torso, and we publish this knowledge hub because the science of staying warm should be public. HEATJAC products are not medical devices and are not intended to diagnose, treat, cure or prevent any disease.