What is heat flux, and how is it measured?

Science of WarmthUpdated 10 min read

Heat flux is the rate of heat transfer through a surface per unit area, measured in watts per square meter (W/m²). It tells engineers how fast heat moves through a wall, a garment or a battery enclosure, and multiplying it by the area gives the total heating or cooling power in watts.

What is heat flux?

Heat always moves from a warmer place to a cooler one. Heat flow, measured in watts, tells you how much energy crosses a boundary each second. Heat flux, written q or q″, divides that flow by the area it passes through. The result is a density: watts per square meter.

Working per square meter makes very different objects comparable. A building wall, a jacket panel, a person’s skin and a small electronics housing all have different sizes, but their heat flux values can sit side by side in one table. Once you know the flux, the total heat flow follows from a single multiplication:

Q = q × A, where Q is heat flow in watts, q is heat flux in W/m² and A is area in m².

Heat flux has a direction. In cold weather the flux through a jacket points outward, from skin to air. On a sunny surface the radiant part points inward. Engineers usually report the net value, the balance of everything flowing in and out.

Heat flux is carried by the three familiar mechanisms: conduction through solids and still air, convection into moving air or water, and radiation between surfaces. The four ways the body loses heat add a fourth route, evaporation of sweat, which matters for people and for any wet surface.

What is the heat flux formula?

There is one formula for each mechanism. They share the same logic: a temperature difference drives heat, and a material or surface property sets how fast it flows.

  • Conduction (Fourier’s law): q = k × ΔT / L for a flat layer, where k is thermal conductivity in W/m·K, ΔT is the temperature difference across the layer and L is its thickness in meters. See thermal conductivity explained.

  • Convection (Newton’s law of cooling): q = h × ΔT, where h is the convective heat transfer coefficient in W/m²·K and ΔT is the difference between the surface and the moving air or liquid.

  • Radiation (Stefan-Boltzmann law): q = ε × σ × (T₁⁴ minus T₂⁴), where ε is surface emissivity, σ is 5.67 × 10⁻⁸ W/m²·K⁴ and temperatures are absolute, in kelvin. See radiant heat loss explained.

A temperature difference of 1 K is the same size as 1 °C, and equal to a difference of 1.8 °F. That is why heat flux formulas can use either kelvin or degrees Celsius for ΔT, as long as the radiation formula uses absolute temperature.

Thermal resistance, R, is the temperature difference needed to push one watt through one square meter. Its unit is m²·K/W. For a single flat layer, R equals thickness divided by conductivity, so Fourier’s law becomes a clean ratio:

q = ΔT / R

Layers in series add their resistances, just like resistors in an electrical circuit. The thin film of air on each surface also counts, and its resistance is 1 divided by the surface heat transfer coefficient. The inverse of the total resistance is the overall heat transfer coefficient, U, in W/m²·K, so q = U × ΔT. Our guides to the heat transfer coefficient and to R-value, clo and tog show how these units convert into clothing ratings.

Worked example: how much heater power does a cold enclosure need?

Picture an insulated box that holds a lithium battery pack outdoors. Its outer surface area is 0.2 m². The insulation plus the outside air film give a total thermal resistance of 0.5 m²·K/W. The pack must stay at 10 °C (50 °F) while the air outside sits at -30 °C (-22 °F).

  1. Temperature difference: 10 minus (-30) = 40 K, a difference of 72 °F.

  2. Heat flux: q = 40 / 0.5 = 80 W/m².

  3. Heat flow: Q = 80 × 0.2 = 16 W.

  4. Energy for an 8-hour shift: 16 W × 8 h = 128 Wh.

Doubling the insulation resistance to 1.0 m²·K/W halves the flux to 40 W/m² and the steady heater power to 8 W. That single step is often the cheapest way to extend runtime, and it is the reasoning behind how battery pack heaters work. Real enclosures also lose heat through seams, cable glands and mounting points, and they need extra energy to warm up from a cold start, so measured values usually run above this steady-state estimate.

What are typical heat flux values?

Heat flux spans an enormous range, from a few watts per square meter through a well-insulated wall to tens of thousands in a fire. The table puts everyday and engineering examples on one scale.

SituationTypical heat fluxSource note
Insulated wall, U of 0.3 W/m²·K, 30 K indoor to outdoor differenceAbout 9 W/m²Calculated with q = U × ΔT
Battery enclosure in the worked example above80 W/m²Calculated with q = ΔT / R
Resting adult, heat produced per square meter of skinAbout 58 W/m², defined as 1 metASHRAE Handbook, Fundamentals
Bright sunlight on a surface facing the sun at sea levelAbout 1,000 W/m², the standard test valuePVEducation, AM1.5G spectrum
Upper limit of total heat loss measured on a sweating hot plateUp to 1,300 W/m²ASTM F1868 scope
Radiant exposure used in fire research and testingUp to 100 kW/m²NIST, Journal of Research

The human figure is a useful anchor. ASHRAE notes that a resting adult produces about 350 Btu/h of heat, roughly 100 W, and that most of it leaves through the skin. Spread over the skin, that is close to 58 W/m². Clothing has to manage a flux of that size, which is why a few W/m² of extra loss through a thin spot or a gap at the waist is something you can feel.

How does a heat flux sensor work?

Most heat flux sensors, also called heat flux transducers or heat flow meters, are thin plates with a known thermal resistance. Many small thermocouple junctions are wired in series across that plate to form a thermopile. When heat passes through the plate, a small temperature difference appears across it, and the thermopile turns that difference into a voltage.

Because the plate’s resistance is fixed, the voltage is proportional to the heat flux. The ratio between them is the sensitivity, usually quoted in microvolts per W/m². Each sensor is calibrated against a known heat flux, and NIST runs calibration programs covering conduction, convection and radiation.

A heat flux sensor measures only what passes through its own footprint, and it changes the surface it sits on. ASTM C1046 lists the main sources of error:

  • Added resistance: the sensor is an extra layer, so it can divert heat around itself. On a highly conductive surface such as sheet metal, the sensor can become the most significant thermal feature at that spot.

  • Calibration that depends on the site: a given calibration is not valid for every mounting, so the conversion factor must be confirmed for the conditions of use.

  • One point is not the whole surface: a single sensor site does not represent a whole component, so multiple sites are used, often chosen with infrared thermography.

  • Changing conditions: heat flux is rarely steady outdoors, so building measurements may run for several days.

Two more practical issues follow from the physics. Air gaps under the sensor add contact resistance, which is why sensors are bonded or pressed flat. And if the sensor’s surface absorbs or emits infrared differently from the surface around it, it will intercept a different share of radiant heat; matching the emissivity of the surrounding surface reduces that error.

How do you measure the heat loss of a garment or enclosure?

The method depends on what you are testing. Established standards give repeatable answers for each case.

  • Building walls and envelopes: ISO 9869-1 and ASTM C1155 use heat flow meters and temperature sensors mounted on an existing wall to estimate its in-place thermal resistance. ASTM C1046 covers how to mount and use the sensors.

  • Clothing materials: ASTM F1868 measures the thermal resistance, evaporative resistance and total heat loss of fabrics, films, foams and multi-layer assemblies on a heated, sweating hot plate.

  • Whole garments and ensembles: ASTM F1291 measures the insulation of a clothing ensemble on a heated manikin in a calm, cool environment. Our guide to how clothing warmth is tested explains the manikin methods in plain language.

  • Product enclosures and heated devices: a common approach is an energy balance. Hold the inside at a set temperature in a cold room, log the electrical power the heater needs once temperatures are steady, and divide by the surface area to get the average heat flux.

The energy balance and the heat flux sensor answer complementary questions. The first gives the total heat loss of the whole object. The second shows where on the surface that loss is concentrated, which tells a designer where extra insulation or a better seal will do the most good.

The HEATJAC Thermal Lab helps other companies answer these questions for products that must work in cold or heat. It measures warm-up behavior, temperature distribution, stability and energy use, using thermal imaging and multi-point temperature logging.

Key takeaways

  • Heat flux is heat flow per unit area, in W/m²; multiply by area to get watts.

  • For a layer or a stack of layers, heat flux equals the temperature difference divided by the total thermal resistance.

  • A resting adult produces about 58 W/m² of skin area, the value defined as 1 met.

  • Thermopile heat flux sensors measure local flux but disturb the surface they sit on, so mounting, calibration and sensor placement matter.

  • Standards such as ISO 9869-1, ASTM C1155, ASTM F1868 and ASTM F1291 cover walls, clothing materials and whole garments.

Frequently asked questions

What are the units of heat flux?

The SI unit is watts per square meter (W/m²). In US engineering you may also see Btu per hour per square foot; 1 Btu/h·ft² equals about 3.15 W/m².

Is heat flux the same as heat flow?

No. Heat flow is the total rate of energy transfer in watts. Heat flux is that rate divided by area, in W/m². A large surface with a low flux can lose more total heat than a small surface with a high flux.

What is the formula for heat flux?

For conduction through a flat layer, q = k × ΔT / L, which is the same as ΔT divided by thermal resistance. For convection, q = h × ΔT. For radiation, q = ε × σ × (T₁⁴ minus T₂⁴), with temperatures in kelvin.

How does a heat flux sensor work?

It is a thin plate of known thermal resistance with a thermopile across it. Heat passing through creates a small temperature difference, the thermopile converts it to a voltage, and a calibration factor turns that voltage into W/m².

How do you calculate heater power from heat flux?

Multiply the heat flux by the surface area. An enclosure losing 80 W/m² over 0.2 m² needs about 16 W to hold its temperature once it is warm, plus extra energy to warm up from cold.

Sources

  1. ASHRAE Handbook, Fundamentals, Chapter 9: Thermal Comfort, ASHRAE

  2. ASTM C1046: Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components, ASTM International

  3. ASTM C1155: Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data, ASTM International

  4. ASTM F1868: Standard Test Method for Thermal Resistance, Evaporative Resistance, and Total Heat Loss Measurements of Clothing Materials Using a Sweating Hot Plate, ASTM International

  5. Calibration of High Heat Flux Sensors at NIST, Journal of Research of the National Institute of Standards and Technology (1997)

  6. Air Mass and the standard solar spectrum, PVEducation

About HEATJAC. HEATJAC is a thermal architecture company founded by an anesthesiologist. We design garment systems that help the body keep its own heat and spread added warmth across the torso, and we publish this knowledge hub because the science of staying warm should be public. HEATJAC products are not medical devices and are not intended to diagnose, treat, cure or prevent any disease.