What is MIL-STD-810 cold testing? Low temperature Method 502 explained
MIL-STD-810 cold testing is the US Department of Defense laboratory method for showing how equipment survives and works in low temperatures. Method 502.7 runs three procedures (storage, operation and manipulation) at temperatures tailored to where the item will serve, from basic cold near -32 °C (-25 °F) to severe cold at -51 °C (-60 °F).