THERMAL LAB · MA-02 · MATERIALS
Aerogel and foam insulation
Insulation works by holding gas still. The smaller the pockets of gas, the less heat gets across. Aerogels take that to its limit, and foams offer a practical middle ground.
Thermal conductivity
Insulation is rated by thermal conductivity, in W/m·K. Lower is better. Resistance to heat flow is thickness divided by conductivity, so a material with half the conductivity does the same job at half the thickness.
| Material | Typical conductivity, W/m·K |
|---|---|
| Silica aerogel composites | 0.013 to 0.020 |
| Still air | About 0.026 |
| Closed-cell polymer foams | 0.030 to 0.040 |
| Fleece and fibrous battings | 0.035 to 0.050 |
| Solid polymers | 0.2 to 0.4 |
Aerogels beat still air because their pores are smaller than the distance air molecules travel between collisions, which suppresses conduction through the gas.
Aerogel in practice
Pure silica aerogel is brittle and dusty. Usable products embed aerogel particles in a foam, a fiber mat or a coating. The composite is flexible and handles well, and its conductivity is higher than the pure material because the binder conducts.
Strengths: best performance per millimeter, wide temperature range. Weaknesses: cost, variable particle distribution, dust from some products, limited stretch.
Closed-cell foams
Polyethylene, EVA and similar foams trap gas in sealed cells. They are consistent, inexpensive, washable and available everywhere. They compress under load and recover, which makes them comfortable and costs some performance while squeezed.
Air-gap structures
A spacer fabric or a dimpled layer holds two surfaces apart with mostly air between. The insulation is the air. Such structures breathe and weigh very little. They rely on the air staying still, so they work best in enclosed positions.
What to check
- Conductivity at the thickness you will actually use.
- Thickness and conductivity under the compression the product will see.
- Whether perforations or stitching create paths for heat.
- Behavior at the temperature of the hot face.
- Lot to lot consistency.
Choosing
For a layer a few millimeters thick, the gap between a good foam and an aerogel composite is real and modest. Consistency, compression behavior and supply often decide the matter. See the program on thin insulation and the Knowledge article on aerogel clothing insulation.