THERMAL LAB · ME-09 · METHODS
Method: cold conditions testing
A system that works at room temperature has passed the easy test. Cold changes materials, batteries and the heat budget itself. Cold testing repeats the key measurements at the temperatures the product will actually meet.
In this section
- ME-01 How we test
- ME-02 Method: thermal imaging
- ME-03 Method: contact temperature sensing
- ME-04 Method: power and energy measurement
- ME-05 Method: warm-up curves
- ME-06 Method: steady state and stability
- ME-07 Method: temperature uniformity
- ME-08 Method: side-by-side comparison
- ME-09 Method: cold conditions testing
- ME-10 Method: surface temperature limits
- ME-11 Method: repeatability and uncertainty
- ME-12 Standards we reference
- ME-13 Reading a thermal report
What cold changes
| Component | Effect of cold |
|---|---|
| Heat budget | Losses grow with the temperature difference |
| Batteries | Less capacity, lower voltage under load, restrictions on charging |
| Self-regulating elements | Lower resistance when cold, so higher starting current |
| Plastics and foams | Stiffer, sometimes brittle |
| Adhesives and laminates | Can lose bond or crack when flexed |
| Displays and buttons | Slower response, stiffer action |
| Moisture | Condensation when a cold item returns to warm air |
Three kinds of cold test
Cold soak. The item is held at the low temperature, unpowered, until it is cold all the way through. This checks that nothing is damaged by the cold itself.
Cold start. From a soaked state, power is applied. Warm-up time, starting current and whether the system starts at all are recorded.
Cold operation. The item runs at the low temperature for the intended duration. Temperature held, energy used and run time are recorded and compared with room temperature results.
Batteries
A pack that gives full capacity at 20 °C (68 °F) gives noticeably less at -10 °C (14 °F), and less still under a heavy load. For a wearable, the fairer test places the pack where it is worn, inside the outer layer near the body, because that is the temperature it actually sees.
Wind
Still cold air and moving cold air are different conditions. Air movement strips heat from an outer surface and pumps air through openings. Where wind matters to the product, we test with controlled air movement and state the speed.
Reference standards
Environmental test standards such as MIL-STD-810 Method 502 describe procedures for low temperature storage and operation. We use such documents as references for procedure. Our development testing is not a certification to any of them. See the Knowledge article on MIL-STD-810 cold testing.
Returning to warm air