What cold changes

ComponentEffect of cold
Heat budgetLosses grow with the temperature difference
BatteriesLess capacity, lower voltage under load, restrictions on charging
Self-regulating elementsLower resistance when cold, so higher starting current
Plastics and foamsStiffer, sometimes brittle
Adhesives and laminatesCan lose bond or crack when flexed
Displays and buttonsSlower response, stiffer action
MoistureCondensation when a cold item returns to warm air

Three kinds of cold test

Cold soak. The item is held at the low temperature, unpowered, until it is cold all the way through. This checks that nothing is damaged by the cold itself.

Cold start. From a soaked state, power is applied. Warm-up time, starting current and whether the system starts at all are recorded.

Cold operation. The item runs at the low temperature for the intended duration. Temperature held, energy used and run time are recorded and compared with room temperature results.

Batteries

A pack that gives full capacity at 20 °C (68 °F) gives noticeably less at -10 °C (14 °F), and less still under a heavy load. For a wearable, the fairer test places the pack where it is worn, inside the outer layer near the body, because that is the temperature it actually sees.

Wind

Still cold air and moving cold air are different conditions. Air movement strips heat from an outer surface and pumps air through openings. Where wind matters to the product, we test with controlled air movement and state the speed.

Reference standards

Environmental test standards such as MIL-STD-810 Method 502 describe procedures for low temperature storage and operation. We use such documents as references for procedure. Our development testing is not a certification to any of them. See the Knowledge article on MIL-STD-810 cold testing.

Returning to warm air

A cold item brought into a warm room collects condensation. We let items return to room temperature in a sealed bag before opening or powering them, and we record it.

Put the lab to work.

Send a brief. A mutual nondisclosure agreement comes first.

Start a program