THERMAL LAB · ME-07 · METHODS
Method: temperature uniformity
Two heaters can share an average temperature and feel nothing alike, because one is even and the other has a hot stripe and cold margins. Uniformity is the measure of that difference, and it is one of the first things we check.
In this section
- ME-01 How we test
- ME-02 Method: thermal imaging
- ME-03 Method: contact temperature sensing
- ME-04 Method: power and energy measurement
- ME-05 Method: warm-up curves
- ME-06 Method: steady state and stability
- ME-07 Method: temperature uniformity
- ME-08 Method: side-by-side comparison
- ME-09 Method: cold conditions testing
- ME-10 Method: surface temperature limits
- ME-11 Method: repeatability and uncertainty
- ME-12 Standards we reference
- ME-13 Reading a thermal report
Why uniformity matters
A hot spot sets the limit for the whole element. If one region is 10 °C (18 °F) above the rest, the entire heater has to be turned down until that region is acceptable, and the rest of the area delivers less than it could. An even element can run closer to its limit everywhere and deliver more useful heat.
How we measure it
A thermal image is taken at steady state with fixed distance, angle and emissivity. Regions of interest are drawn over the active area, defined the same way for every sample.
| Figure | Definition |
|---|---|
| Mean | Average temperature over the active area |
| Maximum and minimum | Hottest and coolest points in the area |
| Spread | Maximum minus minimum |
| Standard deviation | How tightly values cluster around the mean |
| Edge to center difference | Whether heat reaches the margins |
Contact sensors at the center and near an edge confirm the absolute values.
Common patterns
- Hot center, cool edges. Heat escapes at the margins. Usual in small elements.
- Stripes. Heating traces with gaps between them and no spreading layer.
- A hot corner. Often a connection point or a manufacturing variation.
- Patches under perforations or seams. The covering layer is uneven and not the element.
Uniformity of the air, not only the element
For a wearable, the element is a means. What matters is how evenly the air under the outer garment warms. We measure that with sensors spread across a torso form, front and back, and report the spread between the warmest and coolest positions.
Improving it
Uniformity can be improved at the source, with a more even element. It can also be improved in the stack, with a spreading layer or an air gap that lets heat even out before it reaches anything that matters. Both routes are discussed in heat spreaders.
Related program: heating elements.