THERMAL LAB · ME-01 · METHODS
How we test
Every test in our lab follows the same four principles. Define the question. Control the conditions. Record everything on one timeline. State only what the data supports.
In this section
- ME-01 How we test
- ME-02 Method: thermal imaging
- ME-03 Method: contact temperature sensing
- ME-04 Method: power and energy measurement
- ME-05 Method: warm-up curves
- ME-06 Method: steady state and stability
- ME-07 Method: temperature uniformity
- ME-08 Method: side-by-side comparison
- ME-09 Method: cold conditions testing
- ME-10 Method: surface temperature limits
- ME-11 Method: repeatability and uncertainty
- ME-12 Standards we reference
- ME-13 Reading a thermal report
1. Define the question
A test without a question produces numbers and no decision. Before a run we write down what is being decided. Which of two elements warms the air gap faster. Whether a layer change raises the skin-side temperature. How many watt-hours an hour of use costs. The question fixes what is measured and where.
2. Control the conditions
A thermal result depends on its surroundings. Room temperature, air movement, the surface under the sample and the starting temperature all change the outcome. For each run we fix and record:
- Ambient temperature and whether the air is still.
- The starting temperature of the item, after a rest long enough to settle.
- The layer stack around the item, in order.
- The electrical input, measured and not assumed.
- The position of every sensor.
3. Record everything on one timeline
We record thermal images, contact temperatures and electrical power together, with a shared clock. A hot spot in an image can then be matched to what the element was drawing at that second and to what the air gap did afterward.
4. State only what the data supports
A bench measurement of a heating element describes that element in that stack under those conditions. It does not describe how a person will feel, and it is not a health claim. We keep three kinds of statement apart.
| Statement | Basis |
|---|---|
| Material rating | The material maker's test under a named standard |
| Bench measurement | Our own recorded runs |
| Wearer experience | Wear trials and reported comfort |
What a client receives
A written report with the question, the conditions, the recorded data, graphs for every measured point and a plain statement of what was found. See reading a thermal report.
Repeatability
A result we cannot repeat is not a result. Runs that matter are repeated, and the spread between repeats is reported with the figure. See repeatability and uncertainty.