Recording the curve

The item rests until it matches room temperature. Power is applied at a fixed setting. Temperatures at the element, in the air gap and on the skin side are logged until they stop rising. Power is logged alongside.

Reading the shape

Most thermal systems rise quickly at first and then flatten toward a final value. Three numbers describe the curve.

FigureMeaning
Time to a set thresholdHow long until the user feels it
Time constantTime to cover about 63% of the total rise
Final temperatureWhere it settles

What the shape reveals

  • A fast element and a slow air gap means the heat is being made and not delivered. Something between the source and the air is holding it back.
  • An overshoot followed by a dip points to control that reacts late.
  • A curve that never flattens means the system has not reached balance within the run, and the final temperature is unknown.
  • A step in the curve often marks a thermostat or a self-regulating element reaching its switching point.

Comparing systems

Two curves on the same axes, with the same start temperature and ambient, show at a glance which system is faster and which ends warmer. These are different virtues. A thin element with little mass warms quickly. A system with more thermal mass is slower and holds its temperature better when power is interrupted.

Why warm-up matters to the wearer

A person who is cold wants warmth in a minute or two. A system that takes fifteen minutes to make a difference will be judged a failure even if its final temperature is excellent. For daily use, the first few minutes of the curve matter most.

Cool-down

The reverse curve, temperature after power is removed, is equally informative. A slow cool-down means the stack is holding heat well. We record both.

Next: steady state and stability.