THERMAL LAB · ME-04 · METHODS
Method: power and energy measurement
Temperature tells you what a heater achieved. Power and energy tell you what it cost. We measure both at the load, on the same timeline as the temperatures, and report energy in watt-hours.
In this section
- ME-01 How we test
- ME-02 Method: thermal imaging
- ME-03 Method: contact temperature sensing
- ME-04 Method: power and energy measurement
- ME-05 Method: warm-up curves
- ME-06 Method: steady state and stability
- ME-07 Method: temperature uniformity
- ME-08 Method: side-by-side comparison
- ME-09 Method: cold conditions testing
- ME-10 Method: surface temperature limits
- ME-11 Method: repeatability and uncertainty
- ME-12 Standards we reference
- ME-13 Reading a thermal report
Power and energy
Power is the rate at which energy is used, in watts. Energy is power added up over time, in watt-hours. A heater drawing 10 W for 3 hours uses 30 Wh. Power decides how warm. Energy decides how long, and how heavy the battery.
Measure, do not assume
A heating element labeled for a given power will draw that power only at its rated voltage and temperature. Real systems differ.
- Battery voltage sags as a pack discharges and as it gets cold.
- The resistance of many elements changes as they warm.
- A thermostat switches the element on and off, so average power is lower than peak.
- Cables and connectors drop voltage.
So we measure voltage and current at the element continuously and calculate power from them.
What we record
| Quantity | Unit | Why |
|---|---|---|
| Voltage at the load | V | The real operating point |
| Current | A | With voltage, gives power |
| Power | W | Heating rate |
| Energy, cumulative | Wh | Cost of the run |
| Duty cycle | % | How hard the control is working |
Energy to hold a temperature
The most useful single figure for a wearable heater is the energy needed per hour to hold a target temperature in a given stack. It folds in the element, the insulation and the control. Two systems can reach the same temperature while one uses half the energy of the other.
Battery capacity
Power packs are labeled in milliamp-hours at the cell voltage, which does not compare across products. We convert to watt-hours and state voltage and amp-hours alongside, for example 37 Wh (3.7 V, 10 Ah). Then we measure what the pack actually delivers to the load, which is lower than the label once conversion losses are counted.
Why this matters to a buyer
Run time claims based on label capacity and rated power are routinely optimistic. A run time derived from measured energy at the load is one a user can rely on.
See warm-up curves for how power and temperature are read together.