THERMAL LAB · ME-03 · METHODS
Method: contact temperature sensing
A contact sensor reports one thing with confidence, its own temperature. Whether that equals the temperature of the surface, the air gap or the skin depends on how it is mounted. Most of the skill in contact sensing is placement.
In this section
- ME-01 How we test
- ME-02 Method: thermal imaging
- ME-03 Method: contact temperature sensing
- ME-04 Method: power and energy measurement
- ME-05 Method: warm-up curves
- ME-06 Method: steady state and stability
- ME-07 Method: temperature uniformity
- ME-08 Method: side-by-side comparison
- ME-09 Method: cold conditions testing
- ME-10 Method: surface temperature limits
- ME-11 Method: repeatability and uncertainty
- ME-12 Standards we reference
- ME-13 Reading a thermal report
Why contact sensors
A thermal camera sees surfaces. The interesting temperatures in a layered system are inside it: the face of an element under a cover, the air between layers, the body side of an insulation layer. Small sensors placed between layers reach those points.
What affects a reading
- Contact. A sensor resting loosely on a surface reads somewhere between the surface and the air. Firm, repeatable contact matters more than sensor grade.
- Mass. A large sensor on a thin film cools the spot it touches.
- Lead wires. Wires carry heat away from the tip. Routing them along the surface for a short distance reduces the error.
- Self-heating and response time. A sensor takes time to reach the temperature of what it touches. Fast events need small sensors.
Where we place sensors
| Position | What it tells us |
|---|---|
| On the element face | The source temperature |
| Skin side of the stack | What reaches the body |
| In the air gap | The microclimate the wearer feels |
| Outer garment surface | What is being lost |
| Ambient | The conditions of the run |
Positions are marked and photographed, so a repeat run uses the same points.
Multi-point logging
One sensor gives a number. Several give a picture of heat moving through the stack, source first, then the air gap, then the far side. The delays between them are as informative as the final values.
Limits per point
Each position has its own acceptable range. The skin-side limit is low. The element face can be higher because nothing touches it. We set limits per sensor and record any excursion.
Checking the sensors
Before a series of runs, all sensors are held together at one temperature and compared. Any that disagree beyond tolerance are replaced. The check is recorded with the data.
Contact sensing and imaging complement each other. See thermal imaging.