Method: contact temperature sensing

A contact sensor reports one thing with confidence, its own temperature. Whether that equals the temperature of the surface, the air gap or the skin depends on how it is mounted. Most of the skill in contact sensing is placement.

In this section
  1. ME-01 How we test
  2. ME-02 Method: thermal imaging
  3. ME-03 Method: contact temperature sensing
  4. ME-04 Method: power and energy measurement
  5. ME-05 Method: warm-up curves
  6. ME-06 Method: steady state and stability
  7. ME-07 Method: temperature uniformity
  8. ME-08 Method: side-by-side comparison
  9. ME-09 Method: cold conditions testing
  10. ME-10 Method: surface temperature limits
  11. ME-11 Method: repeatability and uncertainty
  12. ME-12 Standards we reference
  13. ME-13 Reading a thermal report

Why contact sensors

A thermal camera sees surfaces. The interesting temperatures in a layered system are inside it: the face of an element under a cover, the air between layers, the body side of an insulation layer. Small sensors placed between layers reach those points.

What affects a reading

  • Contact. A sensor resting loosely on a surface reads somewhere between the surface and the air. Firm, repeatable contact matters more than sensor grade.
  • Mass. A large sensor on a thin film cools the spot it touches.
  • Lead wires. Wires carry heat away from the tip. Routing them along the surface for a short distance reduces the error.
  • Self-heating and response time. A sensor takes time to reach the temperature of what it touches. Fast events need small sensors.

Where we place sensors

PositionWhat it tells us
On the element faceThe source temperature
Skin side of the stackWhat reaches the body
In the air gapThe microclimate the wearer feels
Outer garment surfaceWhat is being lost
AmbientThe conditions of the run

Positions are marked and photographed, so a repeat run uses the same points.

Multi-point logging

One sensor gives a number. Several give a picture of heat moving through the stack, source first, then the air gap, then the far side. The delays between them are as informative as the final values.

Limits per point

Each position has its own acceptable range. The skin-side limit is low. The element face can be higher because nothing touches it. We set limits per sensor and record any excursion.

Checking the sensors

Before a series of runs, all sensors are held together at one temperature and compared. Any that disagree beyond tolerance are replaced. The check is recorded with the data.

Contact sensing and imaging complement each other. See thermal imaging.