What steady state means
A system is at steady state when the heat going in equals the heat going out and temperatures stop drifting. We count a run as settled when readings stay within a narrow band for a defined period.
What we look at
| Observation | What it shows |
|---|---|
| Mean temperature at each point | The level delivered |
| Band between highest and lowest | How tight the control is |
| Cycle period | How often the control switches |
| Drift over hours | Whether something is changing slowly |
| Average power | The energy cost of holding the level |
Cycling
A simple thermostat switches fully on and fully off. Temperature at the element rises and falls in a sawtooth. At the element the swing can be several degrees. In the air gap, layers smooth it out, and the wearer may feel nothing. Where the swing is measured matters as much as its size.
Self-regulating elements behave differently. They reduce their own power smoothly as they warm, so the trace is nearly flat without any switching.
Drift
A slow change over hours usually has a physical cause.
- A battery voltage falling as the pack empties.
- A layer slowly warming through and changing the balance.
- Room temperature moving.
- Moisture building in a layer.
Recording ambient and voltage alongside lets us tell these apart.
Disturbances
Real use is not steady. We introduce known disturbances and watch the recovery: covering the element, opening the outer layer, moving air across the sample, interrupting power for a set time. A good system returns to its level without overshoot.
Why long runs
Many problems only appear after an hour or more. A run that ends when the temperature first looks stable can miss a slow climb that would breach a limit later. Stability runs last at least as long as the intended use.
See control and limits for the design side.