THERMAL LAB · EN-03 · ENGINEERING NOTES
The watt is the unit of warmth
People talk about warmth in degrees. Engineers have to think about it in watts. Temperature is where things stand. Watts are what is moving, and comfort depends on what is moving.
In this section
- EN-01 Why a heated jacket heats two rectangles
- EN-02 Warm air beats hot pads
- EN-03 The watt is the unit of warmth
- EN-04 What a data sheet does not tell you
- EN-05 Thin is a thermal property
- EN-06 Why we measure in watt-hours
- EN-07 The jacket you already own
- EN-08 The cost of an air leak
- EN-09 Feet and hands follow the core
- EN-10 Heating people, not rooms
- EN-11 Cold is a battery problem too
- EN-12 Why 45 °C is not hot, and why it is
- EN-13 The operating room as a test environment
- EN-14 Designing for the wash
- EN-15 What thermal cameras get wrong
Two people, one temperature
Put a hand on a wooden table and a steel table in the same room. Both are at room temperature. The steel feels cold because it draws heat out of the hand faster. The sensation follows the heat flow and not the temperature of the object.
The same holds for the whole body. A person is comfortable when heat leaves at the rate it is produced. Faster, and they cool. Slower, and they overheat.
The body in watts
| Activity | Approximate heat production |
|---|---|
| Sleeping | 70 to 80 W |
| Sitting or standing quietly | About 100 W |
| Walking | 200 to 300 W |
| Heavy work | 400 W and above |
A resting person must shed about 100 W to stay level. Cold stress begins when the surroundings take more than that. The difference, in watts, is the deficit that clothing or added heat has to cover.
Why this changes design
Described in degrees, the problem sounds like one of making things hotter. Described in watts, it becomes a balance. A deficit of 30 W can be closed by adding 30 W, by cutting losses by 30 W, or by some of each. Cutting losses needs no power.
It also puts added heat in proportion. A 10 W heater covers a third of a 30 W deficit if every watt reaches the body, and much less if half escapes outward.
Reading product claims
A claim that a heater reaches 55 °C (131 °F) says nothing about warmth. A tiny element can be very hot and deliver almost nothing. The useful questions are how many watts, into what, and for how long.
Watts per square meter
Engineers often divide by area. A resting person sheds roughly 55 to 60 W for each square meter of body surface. Clothing insulation is defined against that figure. One clo is the insulation that keeps a resting person comfortable in a room at about 21 °C (70 °F). See clo value explained.
In our reports
Every thermal report we write gives power and energy alongside temperature. Without them, a temperature is half a result. See the heat budget.