The heat budget
A heat budget is a simple account. Heat coming in on one side, heat going out on the other, in watts. If the two sides balance at the temperature you want, the design works. If they do not, no component choice will rescue it.
In this section
- TA-01 What is thermal architecture?
- TA-02 The microclimate: the air you wear
- TA-03 Heat off the skin
- TA-04 The five jobs of a thermal system
- TA-05 The heat budget
- TA-06 Layer order
- TA-07 Zones and placement
- TA-08 Passive first
- TA-09 Control and limits
- TA-10 Power architecture
- TA-11 An architecture, not a garment
- TA-12 Cooling is the same problem, reversed
- TA-13 The HEATJAC design rules
The income side
For a person, the main income is metabolism. A resting adult produces about 100 W. Walking raises that to 200 to 300 W, and hard work goes far higher. Added heat is small by comparison.
| Source | Typical power |
|---|---|
| Adult at rest | About 100 W |
| Adult walking | 200 to 300 W |
| Air-activated body warmer | A few watts each |
| Battery heated garment, medium setting | 7 to 15 W |
The spending side
Heat leaves by radiation, convection, conduction and evaporation. At rest indoors, radiation to cooler surroundings is the largest single route. Outdoors in wind, convection takes over. A wet layer adds evaporation whether you want it or not. The Knowledge article on how the body loses heat covers each route.
What the budget tells a designer
Two conclusions follow from the numbers.
First, saving 10% of what the body already makes is worth as much as a 10 W heater, and it needs no power. That is the case for getting the passive structure right before adding anything.
Second, added heat is scarce, so where it goes matters more than how much there is. Ten watts delivered into the microclimate can be felt across the torso. Ten watts delivered into a patch of skin, with half escaping through the back of the element, cannot.
From watts to watt-hours
Power is a rate. Energy is the total, and for anything battery powered it is the number that sets weight and run time. A 10 W load for 8 hours needs 80 Wh at the heater, more at the battery once losses are counted. We state energy in watt-hours in every report for that reason. See why we measure in watt-hours.